SNT 503S Three Phase Programmable Phantom Load
Large Image:SNT 503S Three Phase Programmable Phantom Load |
Detailed Product Description
APPLICATION:
The instrument is used for the calibration of high accuracy signal source in power system. And it is mainly applied in utilities、Measurement Bureaus、Quality Control System、Science & Technology Unit、and Manufacturers for energy meter、terminals、load control、power quality analysis、reactive compensation and etc.
MAIN FEATURES:
1、Output pure sine power signal with distortion degree 0.03% (typical value).
2、Duplicate each harmonic output on base wave.
3、Frequency output adjust within 40Hz~65Hz, with differentiation 0.002Hz and accuracy 0.002Hz.
4、Phase AB is a frequency standard while phase C is an independent frequency standard, so frequency can be set according to different phases.
5、Phase position can be adjusted within 0~360.
6、Strong loading capacity. It can load with capacitive, reductive, resistive or combined load type, with the load adjust rate better than 0.01%RG.
7、Perfect temperature stability, with the temperature coefficient of core part is below 1PPM.
8、32 digits MCU+DSP CPU, powerful function
9、Weekly wave can reach 50000 point for industrial frequency. It does not need filter for internal signal output and guarantee the accurate wave output.
10、Connection to PC via RS 232 port.
11、Perfect protection for over current、over voltage、over heat、short circuit、open circuit、and over load.
12、Hardware PID, no delay for output, fast response. The output will not be affected by the load change
13、320*240 LCD Display.
14、Open communication protocol
15、Can be with pure capacitive load
16、Calibrating energy meter with PC software
TECHNICAL:
AC Voltage Output (0~264V)
Adjust Fineness: 0.01%RG Accuracy: Better than ±0.05%RG
Stability: Better than ±0.01%RG/1min Stability Time: ±60PPM/ Year
Distortion Degree: Better than 0.1% (Not Capacitive Load) Output Power: 20VA
Full Load Adjust Rate: Less than ±0.01%RG Full Load Adjust Time: Less than 1Ms
Gear Setting: 0~130V, 130V~264V auto change Temperature Float: ±8PPM/℃
AC Current Output (0~6A)
Adjust Fineness: 0.01%RG Accuracy: Better than ±0.05%RG
Stability: Better than ±0.01%RG/1min Stability Time: ±60PPM/ Year
Distortion Degree: Better than 0.1% (Not Capacitive Load) Output Power: 20VA
Full Load Adjust Rate: Less than ±0.01%RG Full Load Adjust Time: Less than 1mS
Gear Setting: 0~1A, 1~6A auto change Temperature Float: ±8PPM/℃
Power Output:
Accuracy: Better than 0.05%RG Stability Degree: Better than 0.01%/1min
Phase Position:
Adjust Range: 0~359.99 degree Differentiation: 0.01 degree
Accuracy: ±0.03 degree
Frequency:
Adjust Range: 40Hz~65Hz Differentiation: 0.002Hz
Accuracy: ±0.002Hz Temperature Float: ±0.5PPM/℃
Stability Time: ±4PPM/Year
Power Factor:
Adjust Range: -1~0~+1 Differentiation: 0.0001
Accuracy: 0.0005