SNT 6038 Three Phase Standard Meter (Class 0.02/0.05)
Large Image:SNT 6038 Three Phase Standard Meter (Class 0.02/0.05) |
Detailed Product Description
Standard meter SNT 6038 is a three phase or single phase electronic standard meter of accuracy class 0.02 or class 0.05. It has been developed for the testing of electronic energy meters by means of meter test bench. It is designed for all modes of operation in three phase systems up to 120A.
Features:
1. High precision and long term stability.
2. Universal unit for many applications.
3. Measuring various kinds of electric parameters in the three-phase or single phase circuit synchronously.
4. Calculating directly the reactive power makes the phase place very accurate in angle measurement.
5. Three energy constants only, leads to simple calibration and reliable result.
6. Have the function of low frequency pulse input to calculate the error.
7. Vector diagram display.
8. Waveform display for voltage¤t of each phase.
9. Analysis and display of harmonics.
10. RS 232 and RS485 interface, can be operated by computer system.
Technical:
Power Supply:
Voltage AC 220V±10%
Frequency 50HZ ±2HZ
Max power consumption 45VA
Using Condition:
Environment temperature: 10℃~30℃
Relative humidity 45%~75%
Outside magnetic intensity ≤0.025mT
Frequency range 45HZ~65HZ
Test Current:
Range 1Ma~120A
Error ±0.02% (50Ma…120A)(relative measurement value)
±0.05% (1…50Ma) (relative range full-scale value)
Current display 1Ma…120A (1A, 10A, 100A)
Error ±0.02% (relative measurement value)
Test Voltage
Range 50V~480V (automatic range switch)
Error ±0.02% (50V…480V)(relative measurement value)
±0.05% (5V…50V)(relative range full-scale value)
Power Measure Error
Active power ±0.02% (relative measurement value) 50V…480V, 0.05A…120A
Reactive power ±0.05% (relative measurement value) 50V…480V, 0.05A…120A
Apparent power ±0.05% (relative measurement value) 50V…480V, 0.05A…120A
Test Power Factor (PF=P/S) Error 0.05%
Display range -1~+1
Measuring Modes
4 wire active / reactive / cross-connected reactive
3 wire active / reactive / cross-connected reactive
2 wire active / reactive
Energy Pulse Input
Frequency 0.5Khz
Voltage 24V
Measurement Range of Input
Rated voltage 50V…480V
Rated current 0.001A…120A
Output TTL pulse, load >2kW
High frequency pulse output: F=500Khz
Low frequency pulse output: F=10HZ
Dimensions 131mm×432mm×470mm
Weight 16kg